Technical specifications

TW PS300

Application

Power supply for the TW Master System

Interface

Digital

RS-485 (Modbus RTU)

Analog output

6x 4...20 mA

Load

Max. 500 Ohm

Connection terminals

1.5 mm^2 (AWG 16)

Error indicator

0 mA

Relay

1x changeover contact 24 V, 1 A, potential-free

Acoustic indicator

Buzzer

Visual display

1x status LED

LED Description

Illuminated blue

Switched on

Illuminated blue and flashing white at the same time

Maintenance mode is activated

Flashing red

Alarm & buzzer

Power supply

100 - 240 VAC, 50 - 60 Hz

Typical power consumption

6 W

Power consumption max.

50 W

Connection

Mains connection cable with safety plug

1 x M20 cable gland

3 x M16 cable gland

1 x M12 industrial plug connector for TW Master System connection

Housing

Housing material

Housing: POM-C

Front panel: Acrylic glass (PMMA)

Dimensions (L x H x D)

203 / 185 / 46 mm incl. screw connections (~ 7.99" / 7.28" / 1.81" incl. screw connections)

weight

1.4 kg (~3.09 lbs)

Operating conditions

Operating temperature

-10 to +50 °C
(with pre-installed mains connection cable +5 °C to +50 °C)

Relative humidity

0 to 95 % rH (non-condensing)

Transportation conditions

Same as storage conditions

Storage conditions

Storage temperature

-20 to +70 °C

Relative humidity

0 to 95 % rH (non-condensing)

Protection class

IP64

Protection class

I

Overvoltage category

OVERVOLTAGE CATEGORY II

Pollution degree

2

Operating height

Max. Altitude 2000 m (6,561 ft)

Installation location

Indoor use only

System compatibility

TW Master series

Warranty period

1 year (EU & USA 2 years)